Medical Examination
JASCO|Spectrofluorometer
The FP-8650 spectrofluorometer uses a uniquely red-sensitive PMT that extends the measurement range from the UV-Visible to the near infrared. Providing excitation wavelengths from 200 to 850 nm and emission detection up to 980nm (1010 nm option). Samples such as carbon nanotubes, porphyrins and other NIR markers can easily be measured. It is especially well-suited for monitoring NIR-labeled biologicals far away from background auto-fluorescence. The compact instrument design incorporates high-speed scanning and automatic cut-off filters to exclude higher-order diffraction for fast, accurate acquisition of single spectra and EEMs (Excitation-Emission-Matrices).
JASCO|UV-Visible/NIR Spectrophotometer
The V-770 UV-Visible/NIR spectrophotometer features a unique single monochromator design for maximum light throughput with excellent absorbance linearity. A PMT detector is used for the UV to visible region and a Peltier-cooled PbS detector for the NIR region to 2700 nm (option 3200 nm).
JASCO|Column Ovens
For GPC and larger preparative columns, select either of the two high-capacity CO-4060 or CO-4065 HPLC column ovens. The CO-4060 can accommodate columns with lengths up to 300mm or larger ID preparative columns. The CO-4065 can accommodate up to 10 columns with lengths up to 300mm and a pair of column selection valves is included as standard.
EYELA|Low Temp. Circulation Bath
Developing based on the concept of laboratory security / safety and environment friendly. Compact size realizes in fume hood or under lab table.
EYELA|Aluminum Block Cryostat
Aluminum block cooling system provides safe and stable temperature control as low as -80℃ or -100℃ which cannot be obtained by dry-ice/acetone mixture or ice.
JASCO|Film Holders for V-700
Measure the transmittance of solid, transparent samples such as films, plate glass, and filters. The FLH-740 includes leaf-springs for holding the sample and the FLH-741 includes a sliding clamp and mask for small area measurement. RSH-744 can be rotated 360° with respect to the optical axis and the inclination/tilt of the sample versus the source beam can be varied within a range of ±50°. VTA-752 is used to measure transmittance of a film-like sample when the incident angle of the light beam is varied. This incident angle can be set in 1º increments with a rotation range of ±90°.
EYELA|Forced Air Flow Oven
Forced air flow convection system with programming and self-diagnosis functions.
J-SCIENCE | Hydrogen in Steel Measuring System
This instrument is based on the thermal desorption method of gas chromatography and is used to measure hydrogen that may cause delayed fracture in steel materials. The system allows for continuous batch measurement of hydrogen and validates its behavior with temperature variations. Additionally, it displays data such as temperature and quantity of hydrogen released in measurement result lists and charts, thus verifying the behavior of hydrogen.
HETTICH|Benchtop Centrifuges
High performance unit supporting a wide array of accessories for multiple applications in just one rotor. Its size and performance makes it the ideal bench top centrifuge for most clinical, research and industrial laboratories.
HETTICH|Benchtop Centrifuges
This powerful unit is capable of virtually any application you choose. It is able to spin high sample volumes of blood tubes, conical tubes, plates and bottles. Speciality buckets are able to accommodate 450 ml blood bags.This unit is available with refrigeration and a temperature range from -20 °C to +40 °C (ROTANTA 460 R).
CRYOPAL|Self-pressurized Vessels
Self-pressurized aluminum containers, TPs are designed for storing and dispensing liquid nitrogen at low pressure.