• JASCO|60 mm Integrating Sphere  for V-700

JASCO|60 mm Integrating Sphere for V-700

Integrating spheres measure either the diffuse transmittance or reflectance of a liquid, solid or powder samples. Typically UV-Visible or UV-Visible/NIR spectrophotometers are used to measure the transmittance of a homogeneous, transparent liquid or solid sample. However, when the light is diffusely scattered by samples such as suspended liquid, opaque solid or powders only a small portion of the light reaches the detector. An integrating sphere captures most of the light from the sample offering a more representative measurement of the sample.
Model : ISV-922、ISN-923、ISN-901i

Feature :

  • A smaller surface area, resulting in an increased signal-to-noise ratio for sample measurements at smaller bandwidth settings.
  • Include a Spectralon reference tile and a specular reflectance exclusion sample holder.
  • Provide simple measuring methods for powders, solids and other scattering samples including gem stones.
  • Compliance CIE No.15, ISO 11664-5 ASTM E308, JIS Z 8781-5 etc. colorimetry.
  • Compliance AS/NZS 4399, JIS L1925 BS EN 13758-1, AATCC Test Method 183, GBT18830 UPF Measurement requirements.
  • Compatible haze measurement.
  • For JASCO V-700



Item

ISV-922

ISN-923

ISN-901i

Wavelength range

200 to 870 nm

200 to 2500 nm

200 to 1600 nm

Typical Spectral Bandwidth

5 nm

UV-Vis: 5 nm

NIR: 20 nm

UV-Vis: 5 nm

NIR: 10 nm

Sample Size for Cuvette

(Transmittance Measurement)

Light path length 5, 10, 20, 30, 50 mm rectangular cell (sample side)

Light path length 5, 10, 20, 30, 50 mm rectangular cell (sample side)

Light path length 5, 10, 20, 30, 50 mm rectangular cell (sample side)

Sample Size for Solid Sample

(Transmittance Measurement)

Optional SSH-506 Solid Sample Holder need

Minimum 20 (H) x 20 (W) x 0.5 (D) mm

Maximum 70 (H) x 40 (W) x 35 (D) mm

Minimum 20 (H) x 20 (W) x 0.5 (D) mm

Maximum 70 (H) x 40 (W) x 35 (D) mm

Minimum 20 (H) x 20 (W) x 0.5 (D) mm

Maximum 70 (H) x 40 (W) x 35 (D) mm

Sample Size

(Reflectance Measurement)

Minimum 20 (H) x 20 (W) x 0.5 (Thickness) mm

Maximum 65 (H) x 50 (W) x 25 (Thickness) mm

Minimum 20 (H) x 20 (W) x 0.5 (Thickness) mm

Maximum 65 (H) x 50 (W) x 25 (Thickness) mm

Minimum 20 (H) x 20 (W) x 0.5 (Thickness) mm

Maximum 65 (H) x 50 (W) x 25 (Thickness) mm

Powder Sample volume

(Optional PSH-002 Powder Sample Holder need)

φ 16 mm, 0.5 to 6 mm depth

φ 16 mm, 0.5 to 6 mm depth

φ 16 mm, 0.5 to 6 mm depth

Beam

Approx. 7 mm (Height) x 4 mm (Width) at the position of the transmittance sample

Approx. 8 mm (Height) x 9 mm (Width) at the position of the reflectance sample

Approx. 7 mm (Height) x 4 mm (Width) at the position of the transmittance sample

Approx. 8 mm (Height) x 9 mm (Width) at the position of the reflectance sample

Approx. 7 mm (Height) x 4 mm (Width) at the position of the transmittance sample

Approx. 8 mm (Height) x 9 mm (Width) at the position of the reflectance sample

Inside Diameter of Integrating Sphere

60 mm

60 mm

60 mm

Interior of Integrating Sphere

Coated with barium sulfate

Coated with barium sulfate

Coated with barium sulfate

Detector

Photomultiplier tube

Photomultiplier tube, PbS Detector

Photomultiplier tube, InGaAs Detector

Applicable main models

V-750 and V-760

V-770

V-780


Related Products

JASCO|Micro-Volume Samples for V-700

JASCO|Micro-Volume Samples for V-700

JASCO|Water Thermostatted Cell Holder for V-700

JASCO|Water Thermostatted Cell Holder for V-700

JASCO|150 mm Integrating Sphere  for V-700

JASCO|150 mm Integrating Sphere for V-700

JASCO|Film Holders for V-700

JASCO|Film Holders for V-700