• JASCO|Autosampler║AS-4050

JASCO|Autosampler║AS-4050

The AS-4050 is a 60 sample autosampler for use with conventional HPLC with options for analytical and semi-preparative injection volumes.
Model : AS-4050

Feature :

  • Sample Protection

Peltier control is available for maintaining sample temperature and light protection is available on the higher level models for photo-labile samples.

  • Sample Derivatization and Dilution

Sample preparation is available on the RHPLC and UHPLC autosamplers with programmable sample dilution and pre-column derivitization.

  • Injection Modes

The injection mode can be switched between full loop and partial loop injections.

  • Low Carry-Over

An optional 5 solvent flushing system can be added to virtually eliminate carry-over. An optional degasser can be installed for degassing up to 5 flushing solvents.

  • Maintenance

HPLC autosamplers share the same simple maintenance features, with consumable parts such as injection ports, rotor seals, and loops accessible from the front panel for easy replacement.

Model

AS-4050 (HPLC)

Sample injection method

Full Fill Loop Injection Method, Partially Fill Loop Injection Method (can inject without any sample loss)

Injection volume

0.1 to 100.0 µL (0.1 µL increments) (Sample loop replacement is required.)

1 to 1000 µL (1 µL increments) (Optional large volume injection kit is required.)

Sample loop

100 µL (standard)

Number of samples

60 (standard, 2.0 mL vials)

Reproducibility

0.3 % RSD or less (under specified conditions)

Injection accuracy

±0.1 % or less (can compensate the injection volume by the setting)

Carryover

0.01 % or less (under specified conditions)

Maximum usable pressure

30 MPa

Sample cooling and heating

Option: (Room temperature - 21) °C or 4 °C (whichever is higher) to 40 °C

Pre-column derivatization and dilution

Pre-programmed injection sequence (Two reagent pre-column derivatization is possible)

Dimensions, weight

300 (W) × 470 (D) × 300 (H) mm, without Sample Temperature Control Unit: approx. 21 kg with Sample Temperature Control Unit: approx. 25 kg

Required power

AC 100 to 240 V, 50/60 Hz, without Sample Temperature Control Unit: maximum 60 VA with Sample Temperature Control Unit: maximum 185 VA


Related Products

JASCO|Preparative Autosampler║AS-4058

JASCO|Preparative Autosampler║AS-4058

JASCO|Autosampler║AS-4150

JASCO|Autosampler║AS-4150

JASCO|Autosampler║AS-4250

JASCO|Autosampler║AS-4250

JASCO|Autosamplers(HPLC)║AS-4550

JASCO|Autosamplers(HPLC)║AS-4550

JASCO|Bio-inert Autosampler║AS-4050i

JASCO|Bio-inert Autosampler║AS-4050i