JASCO|UV-Visible/NIR Spectrophotometer║All Series
Feature :
- Compact Design: The compact optical design of the V-700 Series of UV-visible spectrophotometers significantly reduces the requirement for bench space in the modern laboratory.
- Wide Wavelength Range: High energy throughput provides excellent signal-to-noise ratio for the entire UV-visible to NIR spectral range, with detectors selected for the highest sensitivity and dynamic range.
- Excellent Optical Performance: Sophisticated electronic and optical design reduces stray light for highly accurate measurements over a wide photometric range.
- High Speed Scanning: High throughput optics and fast detectors provide high-speed scanning without wavelength tracking errors.
- Dark Correction: Stray light reduction features enable highly-accurate measurements of high-absorbance samples.
- Monochromator Step Scanning: Step scan function provides reliable peak assignment of samples with sharp or narrow absorption peaks.
- User-Friendly: Spectra Manager™ Suite for Windows (with optional 21 CFR part 11 compliance) and iRM hand-held controller for comprehensive control, acquisition, and data processing.
- IQ Accessory: Automatic accessory recognition matches the measurement program to the attached sampling accessory.
- IQ Start: For routine operation, a measurement method can be activated with a simple push of the ‘Start Button’, great for routine operation or speeding up measurement for multiple users.
- Accessories: A comprehensive selection of over 50 sampling accessories for gas, liquid, and solid samples are available for many dedicated sampling applications.
- Regulatory Compliance: For GxP compliant laboratories, instrument validation protocols to USP, EP, and JP are included as standard. IQ/OQ support is also available.
|
Model |
V-730 |
V-750 |
V-760 |
V-770 |
V-780 |
|
Optical System |
Single monochromator, Double beam type |
Single monochromator, Double beam type |
Single monochromator, Double beam type |
Single monochromator, Double beam type |
Single monochromator, Double beam type |
|
Light source |
Halogen lamp, Deuterium lamp |
Halogen lamp, Deuterium lamp |
Halogen lamp, Deuterium lamp |
Halogen lamp, Deuterium lamp |
Halogen lamp, Deuterium lamp |
|
Wavelength range |
190 to 1100 nm |
190 to 900 nm |
187 to 900 nm |
190 to 2700 nm (Option 3200 nm) |
190 to 1600 nm |
|
Wavelength accuracy |
+/-0.2 nm (at 656.1 nm) |
+/-0.2 nm (at 656.1 nm) |
+/-0.1 nm (at 656.1 nm) |
+/-0.3 nm (at 656.1 nm) +/-1.5 nm (at 1312.2 nm) |
+/-0.3 nm (at 656.1 nm) +/-1.0 nm (at 1312.2 nm) |
|
Wavelength repeatability |
+/-0.1 nm |
+/-0.05 nm |
+/-0.05 nm |
+/-0.05 nm (UV-Vis), +/-0.2 nm (NIR) |
+/-0.05 nm (UV-Vis), +/-0.1 nm (NIR) |
|
Spectral bandwidth (SBW) |
1 nm |
0.1, 0.2, 0.5, 1, 2, 5, 10 nm L2, L5, L10 nm (low stray light mode) M1, M2 nm (micro cell mode) |
0.1, 0.2, 0.5, 1, 2, 5, 10 nm L2, L5, L10 nm (low stray light mode) M1, M2 nm (micro cell mode) |
UV-Visible: 0.1, 0.2, 0.5, 1, 2, 5, 10 nm L2, L5, L10 nm (low stray light mode) M1, M2 nm (micro cell mode)
NIR: 0.4, 0.8, 1, 2, 4, 8, 20, 40 L8, L20, L40 nm (low stray light mode) M4, M8 nm (micro cell mode) |
UV-Visible: 0.1, 0.2, 0.5, 1, 2, 5, 10 nm L2, L5, L10 nm (low stray light mode) M1, M2 nm (micro cell mode)
0.2, 0.4, 0.5, 1, 2, 4, 10, 20 nm L4, L10, L20 nm (low stray light mode) M2, M4 nm (micro cell mode) |
|
Stray light |
1 % (198 nm KCL 12 g/L aqueous solution) 0.02 % (220 nm NaI 10 g/L aqueous solution) 0.02 % (340 nm NaNO2 50 g/L aqueous solution) 0.02 % (370 nm NaNO2 50 g/L aqueous solution) |
1 % (198 nm KCL 12 g/L aqueous solution) 0.005 % (220 nm NaI 10 g/L aqueous solution) 0.005 % (340 nm NaNO2 50 g/L aqueous solution) 0.005 % (370 nm NaNO2 50 g/L aqueous solution) |
1 % (198 nm KCL 12 g/L aqueous solution) 0.00008 % (220 nm NaI 10 g/L aqueous solution) 0.00008 % (340 nm NaNO2 50 g/L aqueous solution) 0.00008 % (370 nm NaNO2 50 g/L aqueous solution) |
1 % (198 nm KCL) 0.005 % (220 nm NaI) 0.005 % (340 nm NaNO2) 0.005 % (370 nm NaNO2)
0.04 % (1420 nm: H2O) 0.1 % (1690 nm: CH2Br2) |
1 % (198 nm KCL) 0.005 % (220 nm NaI) 0.005 % (340 nm NaNO2) 0.005 % (370 nm NaNO2) 0.04 % (1420 nm: H2O) |
|
Photometric range |
-3~3 Abs |
-4~4 Abs |
-4~6 Abs |
UV-Visible: -4~4 Abs NIR: -3~3 Abs |
UV-Visible: -4~4 Abs NIR: -3~3 Abs |
|
Photometric accuracy |
+/-0.0015 Abs (0 to 0.5 Abs) +/-0.0025 Abs (0.5 to 1 Abs) +/-0.3 %T Tested |
+/-0.0015 Abs (0 to 0.5 Abs) +/-0.0025 Abs (0.5 to 1 Abs) +/-0.3 %T Tested |
+/-0.0015 Abs (0 to 0.5 Abs) +/-0.0025 Abs (0.5 to 1 Abs) +/-0.3 %T Tested |
+/-0.0015 Abs (0 to 0.5 Abs) +/-0.0025 Abs (0.5 to 1 Abs) +/-0.3 %T Tested |
+/-0.0015 Abs (0 to 0.5 Abs) +/-0.0025 Abs (0.5 to 1 Abs) +/-0.3 %T Tested |
|
Photometric repeatability |
+/-0.0005 Abs (0 to 0.5 Abs) +/-0.0005 Abs (0.5 to 1 Abs) |
+/-0.0005 Abs (0 to 0.5 Abs) +/-0.0005 Abs (0.5 to 1 Abs) |
+/-0.0005 Abs (0 to 0.5 Abs) +/-0.0005 Abs (0.5 to 1 Abs) |
+/-0.0005 Abs (0 to 0.5 Abs) +/-0.0005 Abs (0.5 to 1 Abs) |
+/-0.0005 Abs (0 to 0.5 Abs) +/-0.0005 Abs (0.5 to 1 Abs) |
|
Scanning speed |
10-8000 nm/min |
10-4000 nm/min |
10-4000 nm/min |
10-4000 nm/min |
10-4000 nm/min |
|
RMS noise |
0.00004 Abs |
0.00003 Abs |
0.00003 Abs |
0.00003 Abs |
0.00003 Abs |
|
Baseline stability |
0.0004 Abs/hour |
0.0003 Abs/hour |
0.0003 Abs/hour |
0.0003 Abs/hour |
0.0004 Abs/hour |
|
Baseline flatness |
+/-0.0005 Abs |
+/-0.0002 Abs |
+/-0.0003 Abs |
+/-0.0002 Abs |
+/-0.0002 Abs |
|
Detector |
Silicon photodiode |
Photomultiplier tube |
Photomultiplier tube |
Photomultiplier tube, Peltier cooled PbS |
Photomultiplier tube, Peltier cooled InGaAs photodiode |
|
Integrating Spheres and Absolute Reflectance |
No |
Yes |
Yes |
Yes |
Yes |