JASCO|Infrared Microscope║All Series
Coupling JASCO’s proven technology for infrared spectroscopy with the most advanced optical design, the IRT-5000/7000 Series offers an ideal solution for the most challenging sample analyses.
Feature :
-
Transmission and Reflection with a choice of magnifications.
-
ATR measurement with many prism options including ‘view through’ options.
-
High optical throughput using high quality reflective components
-
Wide wavenumber range 15,000 to 400 cm-1.
-
Excellent signal to noise ratio with a range of MCT and other detectors including electrically cooled DLaTGS.
-
MCT Linear Array Detector (16 elements, wavenumber range 7,000 to 650 cm-1) for fast imaging analysis and kinetics measurement.
-
High spatial resolution.
-
Full vacuum option for sensitive measurement without noise from environmental gases.
-
IQ Mapping for in-situ mapping experiments for high speed or samples that can be easily damaged when the ATR is moved.
-
Rapid IR Imaging experiments for kinetics using Rapid Scan.
-
Spectra Manager Imaging Suite – a fast and powerful interface for mapping and imaging.
-
Up to four objectives with automatic switching.
-
Exceptional visual observation quality with DIC and polarization options.
-
Wide area mapping and multi-ATR imaging.
-
Dynamic Imaging with Rapid Scan and Step-Scan options.
-
Multivariate analysis PCA.
|
Model |
IRT-5100 |
IRT-5200 |
IRT-7100 |
IRT-7200 |
|
Principle |
FTIR microscope with cassegrain optical system |
|||
|
Measurement Method |
Transmittance / Reflectance measurement |
|||
|
Standard Detector |
DLATGS detector (7800-400 cm -1 ) |
Single mid-band MCT (7800-600 cm -1 ) |
Single mid-band MCT (7800-600 cm -1 ) |
Single mid-band MCT
(7800-600 cm -1) (7000-650 cm -1 x 16 element) |
|
Detector Exchange |
Dual detector capability (software controlled), user exchangeable single element detectors are available as an option. |
|||
|
Optional Detectors |
Single
element detector:
(5000-750 cm -1 )
(7800-600 cm -1 )
(7800-450 cm -1 )
(15000-1850 cm -1 ) (12000-4000 cm -1 ) |
Single
element detector:
(5000-750 cm -1 )
(7800-450 cm -1)
(7800-400 cm -1 )
(15000-1850 cm -1 )
(12000-4000 cm -1 ) (7000-650 cm -1),
1 x 16 element (7000-650 cm -1 ),
2 x 16 element (10000-1900 cm -1 ),
1 x 16 element (10000-5000 cm -1 ) , 1 x 16 element |
Single
element detector:
(5000-750 cm -1 )
(7800-450 cm -1 )
(7800-400 cm -1 )
(15000-1850 cm -1 )
(12000-4000 cm -1 ) (7000-650 cm -1 ),
1 x 16 element (7000-650 cm -1 ),
2 x 16 element (10000-1900 cm -1 ),
1 x 16 element (10000-5000 cm -1 ) , 1 x 16 element |
Single
element detector:
(5000-750 cm -1 )
(7800-450 cm -1 )
(7800-400 cm -1 )
(15000-1850 cm -1 )
(12000-4000 cm -1 ) (7000-650 cm -1 ),
2 x 16 element (10000-1900 cm -1 ),
1 x 16 element (10000-5000 cm -1 ) , 1 x 16 element |
|
S/N Ratio |
Single
element detector: (Aperture size 300 μm 2 , resolution 4 cm -1 , 1 min. acquisition, near 2200 cm -1 , p-p) |
Single
element detector: (Aperture size 100 μm 2 , resolution 4 cm -1 , 1 min. acquisition, near 2200 cm -1 , p-p) |
Single
element detector: (Aperture size 100 μm 2 , resolution 4 cm -1 , 1 min. acquisition, near 2200 cm -1 , p-p) |
Single element
detector:
(Aperture size 100 μm 2
, resolution 4 cm -1 , 1 min. acquisition, near 2200 cm -1 , p-p) (Aperture size 12.5 μm 2 , resolution 16 cm -1 , 1 min. acquisition, near 2200 cm -1 , p-p) |
|
Microscope Objectives |
Cassegrain:
16 x 32 x or 10 x |
Cassegrain: 16 x 32 x as standard, 10 x as option
Automatic objective
recognition function (standard) |
||
|
Condenser Mirror |
Cassegrain:
16 x 32 or 10 x
(manual exchange) |
Cassegrain: 16 x, 32 x as standard (manual exchange), 10 x as option |
||
|
Condenser Mirror Compensation |
Standard auto-compensation function |
|||
|
Aperture |
PC-controlled vertical horizontal adjustment and angle of rotation |
|||
|
Sample Storage |
Standard: |
Standard: |
Standard: |
Standard: |
|
Auto Focus |
Option |
Standard |
||
|
IQ Mapping |
- |
Standard |
||
|
Sample Observation |
Standard: |
|||
|
Observation Options |
Visible polarization
observation, Differential interference contrast observation, Fluorescence
observation |
|||
|
Microscope Objectives |
Cassegrain 16× -
standard; 10×, 32× - optional |
|||
|
ATR Measurement (Option) |
"Clear-View"
ATR objective (ATR-5000-SS/SD/SG) , |
|||
|
Grazing Angle Measurement (option) |
Cassegrain grazing angle objective (RAS-5000) |
|||
|
Purge |
Sample area purge case is optional as an option. |
|||
|
Integrated Control Panel |
Transmittance/Reflection
switching with indicator; detector indicator; objective |
|||
|
Dimension |
587 (H) × 302 (W) × 695 (D) mm, 54 kg |
613 (H) × 302 (W) × 695 (D) mm, 56 kg |
||
|
Power Consumption |
AC 100-240 V, 50/60 Hz, max. 60 VA |