• JASCO|Spectrofluorometer

JASCO|Spectrofluorometer

The FP-8250 is a user-friendly, general-purpose instrument. The simplified, yet sensitive design includes everything that is required for routine fluorescence measurements in a quality-control or teaching lab. The standard Auto-Sensitivity Control System (Auto-SCS) and Auto-Gain features enable measurement over a wide range of concentrations using a single calibration method. The Spectra Manager™ Suite of spectroscopy software offers full system control, with easy-to-use tools for data processing and analysis.
Model : FP-8250

Feature :

  • High sensitivity S/N > 4,500 (RMS)
  • Dynamic range up to 7 digits
  • High speed scanning up to 20,000 nm/min
  • Wavelength range: 200 to 750 nm



Model

FP-8250

Light Source

Continuous output Xe arc lamp with shielded lamp housing (150 W)

Light Source (for validation)

Integrated, selectable low pressure mercury lamp

Photometric System

Ratio-photometer system using monochromatic light to monitor the intensity output of the Xe lamp

Monochromator

Holographic concave grating in modified Rowland mount

Ex Wavelength Range (with Standard Detector)

Zero order, 200 - 750 nm

Em Wavelength Range (with Standard Detector)

Zero order, 200 - 750 nm

Ex Wavelength Range (Optional)

-

Em Wavelength Range (Optional)

-

Sensitivity (RMS)

4,500:1

Ex Resolution

1.0 nm (at 546.1 nm)

Em Resolution

1.0 nm (at 546.1 nm)

Ex Band Width

1, 2.5, 5, 10, 20 nm

Em Band Width

1, 2.5, 5, 10, 20 nm

Ex Wavelength Accuracy

±1.5 nm

Em Wavelength Accuracy

±1.5 nm

Wavelength Repeatability

±1.0 nm

Ex Wavelength Scan Speed

20, 50, 100, 200, 500, 1,000, 2,000, 5,000, 10,000, 20,000 nm/min

Em Wavelength Scan Speed

20, 50, 100, 200, 500, 1,000, 2,000, 5,000, 10,000, 20,000 nm/min

Response

10, 20, 50, 100, 200, 500 msec, 1, 2, 4, 8 sec

Detector

Ex: Silicon photodiode, Em: PMT

Photometric Range

-10,000 - 10,000

Sensitivity Selection

High, Medium, Low, Very Low, Manual, Auto SCS

Auto Gain

Standard

Shutter Function

Standard (Automatic control)

Sample Illuminating System

Horizontal illumination

Sample Compartment

10 mm rectangular cell holder, nitrogen purgeable

Recognition of IQ Accessory

Standard

Start Button

Standard

Instrument Communication

USB 2.0

Control and Data Processing

Spectra Manager™ Ver.2.5/CFR