JASCO|Confocal Raman Imaging Microscopes║All Series

The NRS Series of confocal Raman imaging microscopes includes three different optical configurations; the easy to use, yet powerful NRS-4500, with up to three laser wavelengths (wide range, from visible to NIR) including the common dual laser 532/785nm configuration). The sophisticated NRS-5000 Series, with 300mm spectrograph, offering higher spectral and spatial resolution with the use of dual spatial filtration (DSF) and the NRS-7000 Series with 500mm spectrograph and poly-dispersive options. Both the NRS-5000 and NRS-7000 can be configured with up to 8 lasers (9 wavelengths).
Model : NRS Series (NRS-4500、NRS-5500、NRS-5600、NRS-7500、NRS-7600)

Feature :

  • High accuracy spectral resolution, with the use of rotary encoders for the grating drive mechanism to as little as 0.3cm-1 per pixel.
  • High spatial resolution with 0.1µm step, using the automated XYX stage.
  • QRI  – a combination of EMCCD with an ultra-fast XYZ stage giving 0.1µm step resolution QRI increases the data acquisition speed by up to 50x compared with a conventional mapping stage and also offers a significant improvement in sensitivity. Available on all models.
  • Advanced Sample Search – identify target components based on size, shape, color and contrast.
  • IQ-Frame – register and find the exact measurement positions every time in IR and Raman microscopy.
  • SSI using AI algorithms for quickly analysis rough or uneven samples for fast measurement.
  • MCR for component imaging using real-time chemometrics.
  • Advanced Spectral Search for real-time component identification.
  • Long working distance stage and objectives, for larger samples and temperature control and high pressure accessories.
  • Patented Fluorescence Rejection,  an algorithm to reduce or eliminate fluorescence an enhance Raman measurement. Available on all models.
  • Spectra Manager™ Imaging Suite with KnowItAll®, for comprehensive measurement, analysis and reporting. The cross platform software includes the same feature for all NRS models with many options for chemometrics, spectral analysis, etc..

Model

NRS-4500

NRS-5500

NRS-5600

NRS-7500

NRS-7600

Wavenumber Range

8000 to 100 cm-1 (standard)
8000 to 50 cm-1 (optional)

50 ~ 8000 cm-1

10 ~ 8000 cm-1

50 ~ 8000 cm-1

10 ~ 8000 cm-1

Resolution

2 cm-1/pixel (standard)
0.7 cm-1/pixel (optional)

1 cm-1 (standard)
0.4 cm-1 (optional)

0.7 cm-1 (standard)
0.3 cm-1 (optional)

Wavenumber repeatability

± 0.2 cm-1

± 0.1 cm-1

Grating

900 gr/mm (standard)
2400, 1800, 1200, 600, 300, 150 gr/mm  (optional)
(Max. 4 gratings can be mounted)

1800 gr/mm (standard)
3600, 2400, 1200, 600, 300, 150 gr/mm (optional)
(Max. 3 gratings can be mounted)

1800 gr/mm (standard)

3600, 2400, 1200, 600, 300, 150 gr/mm (optional)
(Max. 4 gratings can be mounted)

Detector

Air-cooled Peltier CCD detector (Max. -60°C), 1650 x 200 pixel, 16 µm x 16 µm, Visible to NIR

4-stage Peltier cooled CCD detector (UV-NIR range, 1024 × 255 pixel)
4-stage Peltier cooled CCD detector (high-resolution, 2048
× 512 pixel)
Liquid-nitrogen-cooled InGaAs detector (for 1064 nm excitation laser, 1024 pixel)

Laser

Standard: 532 nm, 20 mW
Optional laser: 405, 442,457,488, 514.5,532,633,785,1064 nm, etc.

Standard: 532 nm, 50 mW
Optional: 244, 266, 325, 355, 442, 488, 514.5, 633, 660, 785, 1064 nm

Number of Mountable Lasers

Maximum 3 lasers (3 internal or 2 internal and 1 external)

Internal: Max. 2 
External: Max. 6
(Vis-NIR laser: Max. 3, UV laser: Max. 3),
Total: Max. 8 lasers, 9 wavelengths

Confocal Optical System

Standard

Standard

Spatial Resolution

XY = 1 µm, Z = 1.5 µm

XY = 0.7 µm, Z = 1 µm

Imaging Measurement

Option, Automatic stage imaging with auto focus, XYZ 0.1 µm step, 3D imaging, omni-focus

Option, Automatic stage imaging with auto focus, XY = 0.04 µm step, Z = 0.1  µm, 3D imaging, omni-focus

Correction Program

Standard, Auto-fluorescence correction, Sensitivity correction, Wavenumber correction

Standard, Auto-fluorescence correction, Sensitivity correction, Wavenumber correction