P-4000 Polarimeters
Feature:
Stable and Accurate Optical Rotation Measurement with P-4000
- Provide line-spectral source: Sodium Lamp and Mercury Lamps
- Sample temperature control and monitoring
- Durable sample compartment
- Instrument validation by using standard quartz control plate with ISO/IEC 17025 compliant
- User-friendly validation and daily check operations
P Proper and Easy Data Management (including 21 CFR part 11)
- User account function
- Data integrity
- Audit Trail
- Electronic signature
- Auto backup function
Supports for data outputs to external devices to meet the user’s purposes
- Export function
- Printer output
- LIMS connection
Optional accessories for comfortable measurement
- JASCO unique rectangular cell with superior usability
- Plenty cell lineup
Hardware
|
Item |
P-4100 |
P-4200 |
P-4300 |
|
Standard Light source |
LED only |
Sodium lamp |
Sodium lamp, Mercury lamp |
|
Optional Light source |
N/A |
Mercury lamp, LED, Tungsten lamp |
LED, Tungsten lamp |
|
Standard Wavelength |
589 nm only |
589 nm |
589, 546, 436, 405, 365 nm |
|
Optional Wavelength |
N/A |
633, 546, 436, 405, 365 nm |
633 nm |
|
Filter changer |
N/A |
N/A |
Standard |
|
Max. path length |
100 mm |
||
|
Measurement angle range |
-90° to 90° |
||
|
Measurement accuracy |
±0.01° ( ≤1°), ±1 % (> 1°) |
±0.002° ( 1°), ±0.2 % (> 1°) |
|
|
Measurement repeatability |
±0.01° |
±0.002° |
|
|
Min. display angle |
0.0001° |
||
|
Sample temperature control |
Standard (Heating/cooling by Peltier effect) |
||
|
Temperature measurement point |
Holder or in-cell sensor |
||
|
Temperature control range |
15 to 40 °C |
||
|
Temperature control accuracy |
±0.2 °C (when using in-cell sensor) |
||
|
Temperature min. display interval |
±0.1 °C |
||
|
Sample compartment exhaust port |
N/A |
Standard |
|
|
Dimensions |
435 (W) × 330 (D) × 210 (H) mm |
550 (W) × 350 (D) × 210 (H) mm |
|
|
Weight |
Approx. 18.5 kg |
Approx. 24.5 kg |
Approx. 25 kg |
Internal control panel
|
Item |
Non-CFR version |
CFR version |
|
Display panel |
Color LCD, 7 inch (1024 × 600 pixels), Touchscreen |
|
|
Applicable language |
Japanese or English |
|
|
Measurement mode |
Optical rotation, specific rotation, concentration, sugar scale, Brix purity, optical purity |
|
|
Daily check |
Light source energy, accuracy of optical rotation |
|
|
Validation |
Applicable for JP, USP, EP, and inspection of instrument performance |
|
|
Self-diagnosis |
Confirmation of instrument condition (light source, temperature senser etc.) |
|
|
Printer |
Windows compatible printer (A4 size) |
|
|
Multi-level user authority |
Available Password setting Access level: 2 Workgroup privileges: N/A |
Available Password setting Access level: 4 Workgroup privileges: 3 |
|
Audit trail |
System, and App logs |
System, App, External event, and Windows event logs |
|
Electronic signature |
Not available |
Available |
|
Data save |
Built-in SSD, USB data storage device (USB flash drive etc) |
Built-in SSD |
|
Data export |
Exports a file in text or csv format to the specified folder. |
LIMS export function |